Skip to content
FIContact usQuote request 0
Fujifilm DRI-CHEM NX10N, Coag-Sense PT2 and Edan i15 side by side

Point-of-care testing

INR, blood gases, blood ammonia and clinical chemistry at the patient's side. Results in minutes from a small sample.

Products

The Coag-Sense PT2 measures PT/INR from a fingertip sample in less than a minute. The portable Edan i15 measures blood gases, electrolytes, glucose, lactate and haematocrit on a single-use cartridge. Fujifilm's DRI-CHEM NX10N measures blood ammonia in about two minutes, and the NX600 measures 15 chemistry tests in about nine minutes.

In Finland we supply point-of-care instruments and accessories from Coag-Sense, Edan and Fujifilm. We install the instruments and train the users.

Applications

Monitoring warfarin therapy

INR in less than a minute

The PT2 measures the true prothrombin time from a 10–12 µl fingertip sample. Each strip pack contains low and high level control strips.

Blood gases and electrolytes

Result in one minute

The i15 measures pH, blood gases, electrolytes, glucose, lactate and haematocrit from a 140 µl sample, or 80 µl with a Microsample cartridge. The battery lasts for 50 samples.

Blood ammonia

In about 2 minutes

The NX10N measures ammonia from a 10 µl whole blood or plasma sample, measuring range 7–357 µmol/l. The instrument weighs 1.2 kg.

Chemistry in the clinic

15 tests in about 9 minutes

The NX600 measures 28 colorimetric tests plus sodium, potassium and chloride without a water connection. The plasma filter separates plasma from whole blood.

Choosing a point-of-care instrument

  • INR is measured with the Coag-Sense PT2, blood gases and lactate with the i15, blood ammonia with the NX10N, and a broader chemistry panel, such as liver and kidney function tests, CRP and electrolytes, with the NX600.

  • The PT2 measures only fresh capillary blood from the fingertip. The i15 cartridge draws in the whole blood sample itself. The NX10N accepts whole blood or plasma, and the NX600 a tube sample.

  • The PT2 weighs 315 g, and its battery lasts for about 100 tests. The i15 runs 50 samples on battery and has a built-in printer. The NX10N weighs 1.2 kg and runs on a power adapter. The NX600 is a benchtop instrument.

  • The PT2 control strips are run for each new strip lot, and the QC lockout prevents patient measurements if a control fails. Quality assurance for the i15 includes a calibrator, 3-level or 5-level controls and an electronic simulator. Fujifilm instruments read the slide lot data from the QC card.

Instruments side by side

Instruments side by side
Coag-Sense PT2Edan i15DRI-CHEM NX10NDRI-CHEM NX600
MeasuresPT and INRpH, pO2, pCO2, Na, K, Ca, Cl, glucose, lactate, haematocritAmmonia28 colorimetric tests plus Na, K and Cl
SampleCapillary blood from the fingertip, 10–12 µlWhole blood 140 µl, Microsample 80 µlWhole blood or plasma, 10 µl10 µl per test, CRP 5 µl
ResultLess than a minuteOne minuteAbout 2 minutes15 tests in about 9 minutes
Quality assuranceControl strips in the pack, QC lockoutCalibrator, controls, electronic simulatorQC card, CONTROL QNQC card, control solutions
PowerBattery, approx. 100 tests per chargeBattery, 50 samples per chargePower adapterMains power
Weight315 g3.65 kg1.2 kg26–28 kg
  • Coag-Sense PT2

    Measures
    PT and INR
    Sample
    Capillary blood from the fingertip, 10–12 µl
    Result
    Less than a minute
    Quality assurance
    Control strips in the pack, QC lockout
    Power
    Battery, approx. 100 tests per charge
    Weight
    315 g
  • Edan i15

    Measures
    pH, pO2, pCO2, Na, K, Ca, Cl, glucose, lactate, haematocrit
    Sample
    Whole blood 140 µl, Microsample 80 µl
    Result
    One minute
    Quality assurance
    Calibrator, controls, electronic simulator
    Power
    Battery, 50 samples per charge
    Weight
    3.65 kg
  • DRI-CHEM NX10N

    Measures
    Ammonia
    Sample
    Whole blood or plasma, 10 µl
    Result
    About 2 minutes
    Quality assurance
    QC card, CONTROL QN
    Power
    Power adapter
    Weight
    1.2 kg
  • DRI-CHEM NX600

    Measures
    28 colorimetric tests plus Na, K and Cl
    Sample
    10 µl per test, CRP 5 µl
    Result
    15 tests in about 9 minutes
    Quality assurance
    QC card, control solutions
    Power
    Mains power
    Weight
    26–28 kg

We install, train and service.

The same specialist handles commissioning and is still there for service years later.

Service and support on weekdays 8.30–16.00+358 10 841 1600huolto@diagnostica.fiRequest service

Frequently asked questions

If you cannot find an answer, call +358 10 841 1600 or email asiakaspalvelu@diagnostica.fi.

Can the PT2 measure a venous sample?

No. The Coag-Sense PT2 measures only fresh capillary blood from the fingertip.

Does the i15 need maintenance?

According to Edan, the i15 requires no maintenance. The cartridges are stored at room temperature.

Which control is used for the NX10N?

Fujifilm's CONTROL QN is an ammonia control for NH3 slides. The pack contains two 3 ml bottles.

What do the instruments cost?

We provide prices in our quote. Tell us your test volume and where the instrument will be used, and we will put together a quote.