Skip to content
FIContact usQuote request 0
Fujifilm, all products from this manufacturer

Fujifilm DRI-CHEM NX10N

Blood ammonia (NH3) analyser for urgent situations. Result from whole blood in about two minutes.

Ask a specialist

Add the product to your quote request and we will tell you the price and delivery time.

  • Result in about 2 minutes, sample 10 µl
  • Measuring range 7–357 µmol/l
  • Weight 1.2 kg, slides for whole blood and plasma
Fujifilm DRI-CHEM NX10N ammonia analyser with a keypad

How the NX10N works

The NX10N measures blood ammonia on FUJI DRI-CHEM slides: NH3-WII for whole blood and NH3-PII for plasma. The measurement is done in five steps, and the result is ready in about two minutes.

Accuracy across the measuring range is ensured with the QC card system. Used slides drop straight into the instrument's waste container, so they do not need to be handled. Results are transferred via USB, and patient data can be entered with the optional barcode reader.

Specifications

Measurement

Analyte
Ammonia (NH3)
Slides
NH3-WII (whole blood), NH3-PII (plasma), 24 slides/pack
Measuring range
7–357 µmol/l (10–500 µg/dl)
Sample volume
10 µl
Measuring time
Approx. 2 min
Quality control
QC card, CONTROL QN control

Instrument

Dimensions
160 × 230 × 93 mm (W × D × H)
Weight
1.2 kg without power adapter
Interfaces
USB
Optional accessories
Barcode reader
Power supply
12 V DC, power adapter 100–240 V
Operating environment
15–32 °C, 30–80% RH

Documents

We supply other documents on request.

Request documents by emailFujifilm: all documents

Five steps to a result

The measurement always proceeds in the same order, and the result is on the display about two minutes after pressing START. The QC card gives the instrument the slide lot data and is used to ensure accuracy across the whole measuring range.

  1. QC cardThe QC card from the slide pack is swiped through the reader
  2. SlideNH3-WII for whole blood or NH3-PII for plasma
  3. Sample10 µl of sample is pipetted onto the slide
  4. STARTThe button starts the measurement
  5. ResultOn the display in about 2 minutes

Accessories

Slides and panels

  • NH3-WII and NH3-PIIAmmonia slides for whole blood (WII) and plasma (PII)24 slides

Controls and calibrators

  • CONTROL QNAmmonia control for NH3 slides3 ml × 2 bottles

Consumables

  • CLEAN TIPSPipette tips96 tips × 6 racks

Optional accessories

  • Barcode readerFor entering patient data

We install, train and service.

The same specialist handles commissioning and is still there for service years later.

Service and support on weekdays 8.30–16.00+358 10 841 1600huolto@diagnostica.fiRequest service
DRI-CHEM NX10N