Skip to content
FIContact usQuote request 0
A dog looking at a Fujifilm DRI-CHEM NX600V analyser

Veterinary

Dry chemistry analysers, haematology analysers and a portable blood gas analyser for veterinary clinics.

Products

Fujifilm's DRI-CHEM NX600V and NX700V measure 23 colorimetric tests plus sodium, potassium and chloride from a 10 µl sample, including canine CRP and lipase. Edan's H30 Vet and H60 Vet give a 3-part or 5-part blood count with species-specific algorithms, and the portable i15 VET measures blood gases, electrolytes and lactate in one minute.

In Finland we supply Fujifilm veterinary DRI-CHEM analysers with their slides and Edan analysers. We install the instruments and train the users.

Applications

Biochemistry in the clinic

1 sample, 128 tests/h

The NX600V measures one sample at a time with ready-made panels. In the IC model, whole blood is centrifuged in the instrument, so plasma is not separated by hand.

High sample volumes

5 samples, 190 tests/h

The NX700V takes five samples at a time and runs an urgent sample mid-run with the STAT function. The range also includes kidney, liver and equine panels.

Blood count

3-part or 5-part

The H30 Vet separates white cells into three groups and the H60 Vet into five. Both have ready-made algorithms for 14 species, and an unlimited number of custom species can be added.

Blood gases and electrolytes

Result in one minute

The i15 VET measures pH, blood gases, electrolytes, glucose, lactate and haematocrit on a single-use cartridge. The instrument is portable and battery-powered.

Choosing instruments for your clinic

  • The DRI-CHEM NX600V and NX700V measure biochemistry tests and electrolytes. The H30 Vet and H60 Vet provide the blood count. The i15 VET measures blood gases, lactate and calcium.

  • The NX600V measures one sample at a time, up to 128 tests per hour. The NX700V takes five samples at a time and measures up to 190 tests per hour. In haematology, the H30 Vet runs 50 and the H60 Vet 60 tests per hour.

  • Edan's analysers have ready-made algorithms for cat, dog, horse, cattle, pig, sheep, goat, rabbit, rat, mouse, monkey, camel, llama and panda. DRI-CHEM's v-LIP-P, v-AMY-P and vc-CRP-P slides are made for veterinary use. The other slides are made for human blood, and according to Fujifilm, results may vary by species. The equine panel is part of the NX700V range.

  • DRI-CHEM uses 10 µl per test, CRP 5 µl and electrolytes 50 µl. The H30 Vet needs 6.5 µl and the H60 Vet 16 µl of whole blood. The i15 VET cartridge needs 140 µl, the Microsample cartridge 80 µl.

  • The i15 VET is battery-powered and has a built-in printer. The cartridges are stored at room temperature. The other instruments are benchtop units weighing 18–33 kg.

NX600V and NX700V

NX600V and NX700V
NX600VNX700V
Tests23 colorimetric tests plus Na, K and Cl23 colorimetric tests plus Na, K and Cl
Throughput120 colorimetric tests/h, 128 in total180 colorimetric tests/h, 190 in total
Samples per run1, continuous loading5, automatic feeding and STAT
Whole bloodIC model separates plasma by centrifugation, approx. 2 min extraNa-K-Cl only
PanelsComprehensive, Pre-Surgical and Plus S-panelAlso Kidney, Liver and Equine panels
InterfacesRS-232C, 2 × USB, LANRS-232C, USB, LAN
Dimensions and weight470 × 360 × 370 mm, 26–27 kg500 × 380 × 410 mm, 33 kg
  • NX600V

    Tests
    23 colorimetric tests plus Na, K and Cl
    Throughput
    120 colorimetric tests/h, 128 in total
    Samples per run
    1, continuous loading
    Whole blood
    IC model separates plasma by centrifugation, approx. 2 min extra
    Panels
    Comprehensive, Pre-Surgical and Plus S-panel
    Interfaces
    RS-232C, 2 × USB, LAN
    Dimensions and weight
    470 × 360 × 370 mm, 26–27 kg
  • NX700V

    Tests
    23 colorimetric tests plus Na, K and Cl
    Throughput
    180 colorimetric tests/h, 190 in total
    Samples per run
    5, automatic feeding and STAT
    Whole blood
    Na-K-Cl only
    Panels
    Also Kidney, Liver and Equine panels
    Interfaces
    RS-232C, USB, LAN
    Dimensions and weight
    500 × 380 × 410 mm, 33 kg

Glossary

S-panel

The slides for one examination, bundled together. The bundle is placed in the slide cartridge and the binding tape is removed.

IC cup

The centrifuge cup of the NX600V IC. After separation, plasma collects at the bottom of the cup, and the instrument measures it from there.

v-LIP-P, v-AMY-P and vc-CRP-P

Lipase, amylase and canine CRP slides made for veterinary use.

QC card

A card in the slide pack from which the analyser reads the lot data.

Microsample

A cartridge version for the i15 VET with a sample volume of 80 µl.

We install, train and service.

The same specialist handles commissioning and is still there for service years later.

Service and support on weekdays 8.30–16.00+358 10 841 1600huolto@diagnostica.fiRequest service

Frequently asked questions

If you cannot find an answer, call +358 10 841 1600 or email asiakaspalvelu@diagnostica.fi.

What is the difference between the NX600V and the NX600V IC?

The IC model has a built-in centrifuge. Whole blood is dispensed into the IC cup, and the instrument separates and measures the plasma itself. Centrifugation adds about two minutes to the measuring time per sample.

Are DRI-CHEM slides suitable for all species?

The v-LIP-P, v-AMY-P and vc-CRP-P slides are made for veterinary use. The other slides are made for analysing human blood, and according to Fujifilm, results may vary by species.

How often do Edan haematology analysers need maintenance?

The H30 Vet every 100 tests and the H60 Vet every 50 tests. The H30 Vet reminds you when maintenance is due.

What do the instruments cost?