Veterinary
Dry chemistry analysers, haematology analysers and a portable blood gas analyser for veterinary clinics.
Products
Fujifilm's DRI-CHEM NX600V and NX700V measure 23 colorimetric tests plus sodium, potassium and chloride from a 10 µl sample, including canine CRP and lipase. Edan's H30 Vet and H60 Vet give a 3-part or 5-part blood count with species-specific algorithms, and the portable i15 VET measures blood gases, electrolytes and lactate in one minute.
In Finland we supply Fujifilm veterinary DRI-CHEM analysers with their slides and Edan analysers. We install the instruments and train the users.
DRI-CHEM NX600V
Dry chemistry analyser for veterinary clinics: 23 colorimetric tests and electrolytes, including canine CRP and lipase.
DRI-CHEM NX700V
Walk-away analyser for veterinary clinics: five samples at a time, up to 190 tests per hour.
H30 Vet
3-part veterinary haematology analyser: 25 parameters from a 6.5 µl sample, 50 tests per hour.
H60 Vet
5-part veterinary haematology analyser: 31 parameters, laser and flow cytometry, 60 tests per hour.
i15
Portable blood gas and chemistry analyser with single-use cartridges: result in one minute. Also available as the veterinary i15 VET.
Applications
Biochemistry in the clinic
1 sample, 128 tests/h
The NX600V measures one sample at a time with ready-made panels. In the IC model, whole blood is centrifuged in the instrument, so plasma is not separated by hand.
High sample volumes
5 samples, 190 tests/h
The NX700V takes five samples at a time and runs an urgent sample mid-run with the STAT function. The range also includes kidney, liver and equine panels.
Blood count
3-part or 5-part
The H30 Vet separates white cells into three groups and the H60 Vet into five. Both have ready-made algorithms for 14 species, and an unlimited number of custom species can be added.
Blood gases and electrolytes
Result in one minute
The i15 VET measures pH, blood gases, electrolytes, glucose, lactate and haematocrit on a single-use cartridge. The instrument is portable and battery-powered.
Choosing instruments for your clinic
The DRI-CHEM NX600V and NX700V measure biochemistry tests and electrolytes. The H30 Vet and H60 Vet provide the blood count. The i15 VET measures blood gases, lactate and calcium.
The NX600V measures one sample at a time, up to 128 tests per hour. The NX700V takes five samples at a time and measures up to 190 tests per hour. In haematology, the H30 Vet runs 50 and the H60 Vet 60 tests per hour.
Edan's analysers have ready-made algorithms for cat, dog, horse, cattle, pig, sheep, goat, rabbit, rat, mouse, monkey, camel, llama and panda. DRI-CHEM's v-LIP-P, v-AMY-P and vc-CRP-P slides are made for veterinary use. The other slides are made for human blood, and according to Fujifilm, results may vary by species. The equine panel is part of the NX700V range.
DRI-CHEM uses 10 µl per test, CRP 5 µl and electrolytes 50 µl. The H30 Vet needs 6.5 µl and the H60 Vet 16 µl of whole blood. The i15 VET cartridge needs 140 µl, the Microsample cartridge 80 µl.
The i15 VET is battery-powered and has a built-in printer. The cartridges are stored at room temperature. The other instruments are benchtop units weighing 18–33 kg.
NX600V and NX700V
| NX600V | NX700V | |
|---|---|---|
| Tests | 23 colorimetric tests plus Na, K and Cl | 23 colorimetric tests plus Na, K and Cl |
| Throughput | 120 colorimetric tests/h, 128 in total | 180 colorimetric tests/h, 190 in total |
| Samples per run | 1, continuous loading | 5, automatic feeding and STAT |
| Whole blood | IC model separates plasma by centrifugation, approx. 2 min extra | Na-K-Cl only |
| Panels | Comprehensive, Pre-Surgical and Plus S-panel | Also Kidney, Liver and Equine panels |
| Interfaces | RS-232C, 2 × USB, LAN | RS-232C, USB, LAN |
| Dimensions and weight | 470 × 360 × 370 mm, 26–27 kg | 500 × 380 × 410 mm, 33 kg |

NX600V
- Tests
- 23 colorimetric tests plus Na, K and Cl
- Throughput
- 120 colorimetric tests/h, 128 in total
- Samples per run
- 1, continuous loading
- Whole blood
- IC model separates plasma by centrifugation, approx. 2 min extra
- Panels
- Comprehensive, Pre-Surgical and Plus S-panel
- Interfaces
- RS-232C, 2 × USB, LAN
- Dimensions and weight
- 470 × 360 × 370 mm, 26–27 kg

NX700V
- Tests
- 23 colorimetric tests plus Na, K and Cl
- Throughput
- 180 colorimetric tests/h, 190 in total
- Samples per run
- 5, automatic feeding and STAT
- Whole blood
- Na-K-Cl only
- Panels
- Also Kidney, Liver and Equine panels
- Interfaces
- RS-232C, USB, LAN
- Dimensions and weight
- 500 × 380 × 410 mm, 33 kg
Glossary
S-panel
The slides for one examination, bundled together. The bundle is placed in the slide cartridge and the binding tape is removed.
IC cup
The centrifuge cup of the NX600V IC. After separation, plasma collects at the bottom of the cup, and the instrument measures it from there.
v-LIP-P, v-AMY-P and vc-CRP-P
Lipase, amylase and canine CRP slides made for veterinary use.
QC card
A card in the slide pack from which the analyser reads the lot data.
Microsample
A cartridge version for the i15 VET with a sample volume of 80 µl.
Manufacturers
Fujifilm: dry chemistry analysersFUJI DRI-CHEM analysers measure clinical chemistry tests from dry slides. No water connection is needed, most tests require no calibration, and results are ready in a few minutes.
Edan: haematology and blood gasesEdan haematology analysers for veterinary clinics and the portable i15 blood gas analyser for point-of-care testing.
We install, train and service.
The same specialist handles commissioning and is still there for service years later.
Frequently asked questions
If you cannot find an answer, call +358 10 841 1600 or email asiakaspalvelu@diagnostica.fi.
What is the difference between the NX600V and the NX600V IC?
The IC model has a built-in centrifuge. Whole blood is dispensed into the IC cup, and the instrument separates and measures the plasma itself. Centrifugation adds about two minutes to the measuring time per sample.
Are DRI-CHEM slides suitable for all species?
The v-LIP-P, v-AMY-P and vc-CRP-P slides are made for veterinary use. The other slides are made for analysing human blood, and according to Fujifilm, results may vary by species.
How often do Edan haematology analysers need maintenance?
The H30 Vet every 100 tests and the H60 Vet every 50 tests. The H30 Vet reminds you when maintenance is due.
What do the instruments cost?
We provide prices in our quote. Tell us your clinic's test volumes and the species you treat, and we will put together a quote.