Fujifilm DRI-CHEM NX600
A dry chemistry analyser that measures 15 tests from one sample in about nine minutes. No water connection and no calibration except for CRP.
Add the product to your quote request and we will tell you the price and delivery time.
- 28 colorimetric tests and 3 electrolytes (Na, K, Cl)
- 15 tests in about 9 minutes, up to 128 tests per hour
- The plasma filter separates plasma from whole blood in a minute

How the NX600 works
The NX600 pipettes the sample onto the slides automatically. Colorimetric tests are ready in 2–6 minutes and electrolytes in one minute. The slides for the next sample can be loaded as soon as pipetting of the previous one is complete.
The plasma filter separates plasma from whole blood in the tube in about a minute, so no separate centrifugation is needed. The analyser has automatic dilution, user IDs and a thermal printer, and used slides drop straight into the waste container.
Results are transferred to the laboratory information system via RS-232C, USB or LAN in accordance with the HL7 standard.
Specifications
Measurement
- Method
- Dry chemistry: colorimetric multilayer slides and ion-selective electrodes
- Test menu
- 28 colorimetric tests plus Na, K and Cl
- Throughput
- 120 colorimetric tests/h, 128 tests/h in total
- Samples per run
- 1, continuous loading
- Measuring time
- Colorimetry 2–6 min/test, electrolytes 1 min/3 tests
- Sample types
- Plasma, serum, whole blood (whole blood only for NH3 and Na-K-Cl)
- Sample volume
- 10 µl/test, CRP 5 µl, electrolytes 50 µl/3 tests
- Calibration
- Not required, except for CRP. Lot correction with QC card
Instrument
- Display
- 7-inch colour touch screen
- Printer
- Thermal printer
- Interfaces
- RS-232C, 2 × USB, LAN, HL7
- Dimensions
- 470 × 360 × 370 mm (W × D × H)
- Weight
- Approx. 28 kg with plasma filter
- Power supply
- 100–240 V, 50–60 Hz, no water connection
- Operating environment
- 15–32 °C, 30–80% RH
Documents
- BrochureEnglish, PDF 1.3 MB
We supply other documents on request.
Request documents by emailFujifilm: all documentsPlasma directly from whole blood
The plasma filter is placed on top of the sample tube, and the measurement is started with the START button. The suction unit connects to the filter and draws whole blood from the tube. A glass fibre layer separates the blood cells, and plasma collects in the filter in less than a minute.
Before use, the filter data are read from the PF card. The filter fits ⌀16 × 100, ⌀13 × 100 and ⌀13 × 75 mm tubes. The NX600i model has no plasma filter.
Accessories
Slides and panels
Controls and calibrators
CONTROL QP-H and QP-LControls for general chemistry and enzyme slides3 ml × 6 bottles
CONTROL QEElectrolyte control for the Na-K-Cl slide1 ml × 10 ampoules
Calibrator CP (CRP)CRP calibrator, three levels1 ml × 3 levels
Consumables
- Reference Fluid REReference fluid dispensed onto the Na-K-Cl slide together with the sample8 ml × 6 bottles
- Diluent DL (CRP)For 21-fold dilution of CRP samples32 ml
PLASMA FILTER PFSeparates plasma from whole blood on top of the sample tube50 pcs
We install, train and service.
The same specialist handles commissioning and is still there for service years later.