Fujifilm DRI-CHEM NX700
A dry chemistry analyser you load with five samples at a time while you get on with other work. No water connection and no calibration except for CRP.
Add the product to your quote request and we will tell you the price and delivery time.
- 5 samples in one run, STAT button for urgent samples
- Up to 190 tests per hour
- 28 colorimetric tests and 3 electrolytes

How the NX700 works
The NX700 handles up to five samples in one run, and an urgent sample can be run in between with the STAT button. 15 tests from one sample are ready in about nine minutes.
Features include a plasma filter, automatic dilution and quality control tools. Ready-made test panels, such as the 12-test comprehensive panel, speed up the most common examinations.
The analyser runs on ordinary mains power without a water connection, compressed air or exhaust ventilation, and results are transferred to the information system in accordance with the HL7 standard.
Specifications
Measurement
- Method
- Dry chemistry: colorimetric multilayer slides and ion-selective electrodes
- Test menu
- 28 colorimetric tests plus Na, K and Cl
- Throughput
- 180 colorimetric tests/h, 190 tests/h in total
- Samples per run
- 5
- Measuring time
- Colorimetry 2–6 min/test, electrolytes 1 min/3 tests
- Sample types
- Plasma, serum, whole blood (whole blood only for NH3 and Na-K-Cl)
- Sample volume
- 10 µl/test, CRP 5 µl, electrolytes 50 µl/3 tests
- Calibration
- Not required, except for CRP. Lot correction with QC card
Instrument
- Display
- 7-inch colour touch screen
- Printer
- Thermal printer
- Interfaces
- RS-232C, USB, LAN, HL7
- Dimensions
- 500 × 380 × 410 mm (W × D × H)
- Weight
- Approx. 33 kg
- Power supply
- 100–240 V, 50–60 Hz, no water connection
- Operating environment
- 15–32 °C, 30–80% RH
Documents
- BrochureEnglish, PDF 3.0 MB
We supply other documents on request.
Request documents by emailFujifilm: all documentsFive samples in one run
The sample tray holds five sample racks. Once the slides and samples are in place and the START button has been pressed, the NX700 does the rest.
An urgent sample is run in the middle of a measurement: press STAT, place the sample and press START. CRP is calibrated on the same tray: the CRP slides, diluent and calibrator are placed on the sample tray, and calibration starts with the Calibration button.
Accessories
Slides and panels
Controls and calibrators
CONTROL QP-H and QP-LControls for general chemistry and enzyme slides3 ml × 6 bottles
CONTROL QEElectrolyte control for the Na-K-Cl slide1 ml × 10 ampoules
Calibrator CP (CRP)CRP calibrator, three levels1 ml × 3 levels
Consumables
AUTO TIPSPipette tips for the analyser576 pcs
HEPARIN TUBE 0.5 and 1.5 mlFuji sample tubes. Ordinary blood collection tubes can also be used.500 pcs
PLAIN TUBE 0.5 and 1.5 mlFuji sample tubes without additive500 pcs
MIXING CUPS50 pcs
PLASMA FILTER PFSeparates plasma from whole blood on top of the sample tube50 pcs- Reference Fluid REReference fluid dispensed onto the Na-K-Cl slide together with the sample8 ml × 6 bottles
- Diluent DL (CRP)For 21-fold dilution of CRP samples32 ml
We install, train and service.
The same specialist handles commissioning and is still there for service years later.